ThinkServerTD350UserGuideandHardwareMaintenanceManualMachineTypes:70DG,70DH,70DJ,70DK,70DL,70DM,70DN,and70DQ

Page 2 - •“Safetyinformation”onpageiii

Statement11CAUTION:Thefollowinglabelindicatesapotentialheathazard.Statement12DANGEROverloadingabranchcircuitisapotentialfirehazardandashockhazardunderc

Page 3 - Contents

10.PositionthenewPCIecardoverthePCIecardslot.Then,carefullypressthePCIecardstraightdownuntilitissecurelyseatedintheslot.Figure47.InstallingthePCIecard

Page 4

•IfyouareinstallinganEthernetcard,continuetoinstalltheEthernetcarddriver.ThisstepisnotrequirediftheoperatingsystemwasinstalledusingtheLenovoThinkServe

Page 5 - Safetyinformation

Figure49.PivotingthelatchforthePCIecardslottotheopenposition8.GraspthePCIecardbyitsedgesandcarefullypullitoutofthePCIecardslot.ThePCIecardfitstightlyin

Page 6

•Tocompletetheremovalprocedure,goto“Completingthepartsreplacement”onpage164.•IfyouareremovingaRAIDcard,reconfigureRAIDforyourserver.See“ConfiguringRAID”

Page 7

9.EnsurethatthetwoholesintheSDmodulearealignedwiththetwoplasticpinsonthesystemboard.Then,lowertheSDmodulestraightdownuntilitissecurelyseated.Figure51.

Page 8

7.Pressthetworeleasetabs1andgrasptheSDmodulebyitsedgesatthesametime.Then,lifttheSDmodulestraightupandoffthesystemboard.Figure52.RemovingtheSDmodule8.P

Page 9

2.Iftheserverisinstalledinarackcabinet,removetheserverfromtherackcabinetandplaceitonaflat,clean,andstatic-protectivesurface.SeetheRackInstallationInstr

Page 10

RemovingtheRAID110iupgradekeyAttention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”onpageiiiand“Guidelines”on

Page 11 - ©CopyrightLenovo2014

5.LocatetheRAID110iupgradekeyonthesystemboard.Then,lifttheRAID110iupgradekeystraightuptoremoveitfromtheupgradekeyconnector.Figure54.RemovingtheRAID110

Page 12 - Safetyinspectionguide

InstallingtheRAID510iupgradekeyAttention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”onpageiiiand“Guidelines”

Page 13 - Groundingrequirements

Statement16CAUTION:Toreducetheriskofelectricshockorenergyhazards:•Thisequipmentmustbeinstalledbytrainedservicepersonnelinarestricted-accesslocation,as

Page 14

Whattodonext:•Toworkwithanotherpieceofhardware,gototheappropriatesection.•Tocompletetheinstallation,goto“Completingthepartsreplacement”onpage164.Then,

Page 15 - Chapter1.Generalinformation

6.RemovetheRAID510iupgradekeyfromtheLenovoThinkServerRAID510iAnyRAIDAdapter.Note:Ifnecessary,removetheLenovoThinkServerRAID510iAnyRAIDAdapterfirstforea

Page 16 - Serverdocumentation

Toinstalltheflashmodule,dothefollowing:1.Removeallmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,disconnectallpowercordsfromelectrical

Page 17 - Chapter1.Generalinformation3

2.Iftheserverisinstalledinarackcabinet,removetheserverfromtherackcabinetandplaceitonaflat,clean,andstatic-protectivesurface.SeetheRackInstallationInstr

Page 18

•UseanydocumentationthatcomeswiththeTSMPremiumandfollowthoseinstructionsinadditiontotheinstructionsinthistopic.•Dependingonthemodel,yourservermightloo

Page 19 - Chapter2.Serversetuproadmap

•Toworkwithanotherpieceofhardware,gototheappropriatesection.•Tocompletetheinstallation,goto“Completingthepartsreplacement”onpage164.Forinformationabou

Page 20

5.LocatetheTSMPremiumonthesystemboard.LifttheTSMPremiumstraightuptoremoveitfromtheconnector.Figure60.RemovingtheTSMPremium6.Ifyouareinstructedtoreturn

Page 21 - Chapter3.Productoverview

InstallingtheTPMAttention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”onpageiiiand“Guidelines”onpage63.Before

Page 22 - Features

6.LocatetheTPMconnectoronthesystemboard.InserttheTPMintotheTPMconnector.Figure61.InstallingtheTPMWhattodonext:•Toworkwithanotherpieceofhardware,gototh

Page 23 - Chapter3.Productoverview9

Notes:•IfyouremovetheTPM,theTPMfunctionwillbeunavailable.•UseanydocumentationthatcomeswiththeTPMandfollowthoseinstructionsinadditiontotheinstructionsi

Page 24

Statement20CAUTION:Alithiumionbatteryisprovided.Toavoidpossibleexplosion,donotburnthebattery.ReplacethebatteryonlywiththeLenovo-approvedpart.Recycleor

Page 25 - Chapter3.Productoverview11

5.LocatetheTPMonthesystemboard.LifttheTPMstraightuptoremoveitfromtheTPMconnector.Note:CarefullyhandletheTPMbyitsedges.Figure62.RemovingtheTPM6.Ifyouar

Page 26 - Specifications

InstallingtheintrusionswitchAttention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”onpageiiiand“Guidelines”onp

Page 27 - Software

RemovingtheintrusionswitchAttention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”onpageiiiand“Guidelines”onpag

Page 28 - Management

•Tocompletetheremovalprocedure,goto“Completingthepartsreplacement”onpage164.InstallingorreplacinganopticaldriveAttention:Donotopenyourserverorattempta

Page 29 - LenovoThinkServerPowerPlanner

Notes:•Dependingonthemodel,yourservermightlookslightlydifferentfromtheillustrationsinthistopic.•Useanydocumentationthatcomeswiththeopticaldriveandfoll

Page 30 - Locations

•Ifyouarereplacinganopticaldrive,disconnectthesignalcableandthepowercablefromtherearoftheopticaldrive.Liftthereleasebutton1inthedirectionasshownandpus

Page 31 - Frontviewoftheserver

8.Connectthepowercable1andthesignalcable2totherearofthenewopticaldrive.Figure68.Connectingcablestotherearoftheopticaldrive9.Ifnecessary,connecttheothe

Page 32

Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanothercomputerforreference.Notes:•Dependingonthemodel,yourservermig

Page 33 - Chapter3.Productoverview19

5.Pullthehandleandcarefullyslidethehot-swapstoragedriveorthedummytrayoutofthefrontofthechassis.Figure70.Removingthehot-swapstoragedriveorthedummytray6

Page 34 - Frontpanel

7.Slidethenewhot-swapstoragedriveintothedrivebayfromthefrontuntilitsnapsintoposition,andthencompletelyclosethehandle.Figure71.Installingthehot-swapsto

Page 35 - Chapter3.Productoverview21

7.Checkinsidetheunitforanyobviousunsafeconditions,suchasmetalfilings,contamination,waterorotherliquids,orsignsoffireorsmokedamage.8.Checkforworn,frayed,

Page 36 - Rearviewoftheserver

ForalistofThinkServerstoragedriveoptions,goto:http://lenovoquickpick.com/usa/home/thinkserver/rack-and-tower-serverTheEMIintegrityandcoolingoftheserve

Page 37

5.Useascrewdrivertoturnthehandlelock1totheunlockedposition.Thehandleopensautomatically.Figure72.Openingthehandleoftheeasy-swapdriveorthedummytrayChapt

Page 38 - Servercoverlock

6.Pullthehandleandcarefullyslidetheeasy-swapdriveorthedummytrayoutofthefrontofthechassis.Figure73.Removingtheeasy-swapdriveorthedummytray7.Dooneofthef

Page 39 - Servercomponents

9.Aligntheholesinthedrivetraywiththecorrespondingonesontheneweasy-swapdrive.Then,installthefourscrewstosecurethedrivetothedrivetray.Figure75.Installin

Page 40

Whattodonext:•Toworkwithanotherpieceofhardware,gototheappropriatesection.•ToconfigureRAID,goto“ConfiguringRAID”onpage58.Installingorreplacinganinternalt

Page 41 - .Productoverview27

•Ifyouarereplacingatapedrive,disconnectthepowerandsignalcablefromtherearofthetapedrive.Liftthereleasebutton1inthedirectionasshownandpushthetapedrivefr

Page 42 - CRUidentification

7.Connectthepowerandsignalcable1totherearofthetapedrive.Figure80.Connectingthepowerandsignalcabletotherearofthetapedrive8.Dooneofthefollowing:•Ifyouar

Page 43 - .Productoverview29

Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanothercomputerforreference.Notes:•Ensurethatyouinstallthecorrecttyp

Page 44 - System-fanstatusLEDs

7.Gentlypressthemicroprocessorretainerasshowntoopenit.Ensurethatthesmallhandlesandthemicroprocessorretainerareinthefullyopenposition.Note:Donotdropany

Page 45 - PowersupplystatusLEDs

10.Notetheorientationofthenewmicroprocessor.Holdthenewmicroprocessorbyitsedgesandalignthenotches1onitwiththetabs2inthemicroprocessorsocket.Then,carefu

Page 46 - 3FaultLED

xiiThinkServerTD350UserGuideandHardwareMaintenanceManual

Page 47 - Chapter3.Productoverview33

12.Closethesmallhandle1firstandthenclosethesmallhandle2tolocktheretainerandsecurethenewmicroprocessorinthesocket.Note:Therearetwomarksonthemicroprocess

Page 48 - 3PCI-E1connector

Notes:•Ensurethatthenewmicroprocessoristhecorrecttypeyourserversupports.Whentwomicroprocessorsareinstalled,bothmusthavethesamecorevoltageandcorespeed.

Page 49 - Chapter3.Productoverview35

7.Gentlypressthemicroprocessorretainerasshowntoopenit.Ensurethatthesmallhandlesandthemicroprocessorretainerareinthefullyopenposition.Figure88.Openingt

Page 50

10.Removethenewmicroprocessorfromtheprotectivecoverthatprotectsthegoldcontactsonthebottomofthenewmicroprocessor.Donottouchthepinsonthemicroprocessorso

Page 51 - Hot-swap-drivebackplane

12.Closethesmallhandle1firstandthenclosethesmallhandle2tolocktheretainerandsecurethenewmicroprocessorinthesocket.Note:Therearetwomarksonthemicroprocess

Page 52 - 16AnyRAID-adapterslots

Whattodonext:•Toworkwithanotherpieceofhardware,gototheappropriatesection.•Tocompletethereplacement,goto“Completingthepartsreplacement”onpage164.Instal

Page 53 - Connectingcables

Notes:•TomaintaintheEMIintegrityandcoolingoftheserver,installanewhot-swapredundantpowersupplyassoonasyouremovethefailingoneorcovertheotherbaywithaprot

Page 54

b.Disconnectthepowercordfromthefailinghot-swapredundantpowersupply.Then,pressthereleasetab1andpullthehandle2atthesametimetoslidethefailinghot-swapredu

Page 55 - Systemboardcomponents

5.Ifyouareinstructedtoreturntheoldhot-swapredundantpowersupply,followallpackaginginstructionsanduseanypackagingmaterialsthataresuppliedtoyouforshippin

Page 56

3.Pullthehandleandcarefullyslidethedummytrayoutofthefrontofthechassis.Figure98.Removingthedummytray4.Touchthestatic-protectivepackagethatcontainsthe2.

Page 57

Chapter1.GeneralinformationThischapterprovidessomegeneralinformationaboutyourproduct.Thischaptercontainsthefollowingitems:•“Introduction”onpage1•“Serv

Page 58 - Systemboardjumpers

5.Positionthe2.5-inchdriveintothe3.5-inchto2.5-inchdriveadapterasshowninthefollowingillustration.Figure99.Positioningthe2.5-inchdriveintothedriveadapt

Page 59 - BIOSrecoveryjumper

7.Positionthedriveadapterandthe2.5-inchdriveintothe3.5-inchdrivebracket.Alignthescrewholesinthedriveadapterandthe2.5-inchdrivewiththecorrespondinghole

Page 60 - 2BIOSdefaultsettingsjumper

11.Savetheremoveddummystorage-drivetrayintheeventthatyoulaterremovethe2.5-inchdriveandneedadummytraytocoverthedrivebay.Whattodonext:•Toworkwithanother

Page 61 - Chapter3.Productoverview47

8.Pressthereleasetab1onthebottomofthefront-panelboardandpullitinthedirectionasshownatthesametime.Then,removethefront-panelboardoutofthechassis.Figure1

Page 62

10.Insertthemetaltabonthetopofthenewfront-panelboardintothecorrespondinghole1inthechassis.Then,pressthereleasetabandpivotthefront-panelboardinwardunti

Page 63 - Turningofftheserver

ThistopicappliesonlytoservermodelsthathaveaThinkServerRAIDSuperCapacitorModuleinstalled.Dependingonthemodel,theservermightcomewithuptothreeThinkServer

Page 64

5.Gentlypressthetab1onthebracketandremovetheThinkServerRAIDSuperCapacitorModulefromthebracketatthesametime.Figure106.RemovingtheThinkServerRAIDSuperCa

Page 65 - Chapter5.Configuringtheserver

8.EnsurethatthescrewholesinthenewThinkServerRAIDSuperCapacitorModulewiththebracketarealignedwiththecorrespondingstubsinthechassis.Then,installthescrew

Page 66 - AdvancedSettingsmenu

2.Iftheserverisinstalledinarackcabinet,removetheserverfromtherackcabinetandplaceitonaflat,clean,andstatic-protectivesurface.SeetheRackInstallationInstr

Page 67 - Save&Exitmenu

•For2.5-inch-driveservermodelsthathaveanAnyRAIDadapterinstalledwithanairductLoosenthescrewthatsecurestheAnyRAID-adapterairduct.Then,liftitinthedirecti

Page 68 - Usingpasswords

Recordinformationaboutyourserverinthefollowingtable.Youwillneedtheinformationifyoueverneedtohaveyourserverserviced.Forwheretofindtheproductinformationl

Page 69 - Selectingastartupdevice

8.LoosenthetwoscrewsthatsecuretheAnyRAIDadapterorthepass-throughboard.Then,grasptheAnyRAIDadapterorthepass-throughboardbyitsedgesandcarefullypullitout

Page 70 - UpdatingorrecoveringtheBIOS

•ToremovetheAnyRAID-adaptertray,pressthereleasetab1.Then,graspthetrayandcarefullypullitoutofthechassis.Figure112.RemovingtheAnyRAID-adaptertray•Torein

Page 71 - Updating(flashing)theBIOS

11.PositionthenewAnyRAIDadapterorthepass-throughboardnearthebackplane.Then,carefullypressthenewAnyRAIDadapterorthepass-throughboardstraightintotheAnyR

Page 72 - AboutRAID

1.Removeallmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,disconnectallpowercordsfromelectricaloutletsanddisconnectallcablesthatareco

Page 73

•Fortheservermodelswith2.5-inch-drivebackplane,pressthereleasetab1andgentlyliftthe2.5-inch-drivebackplanealittlebitupwardsothatitisreleasedfromthehook

Page 74

Note:Theeasy-swap-drivemoduleissensitivetoESD.Ensurethatyoureadandunderstand“Handlingstatic-sensitivedevices”onpage64firstandcarefullyperformtheoperati

Page 75 - Updatingthefirmware

•Toworkwithanotherpieceofhardware,gototheappropriatesection.•Tocompletethereplacementprocedure,goto“Completingthepartsreplacement”onpage164.Replacingt

Page 76

3.PinchtheU-shapedsidesonthetopofthesystemfanandslidethesystemfanoutofthechassis.Figure118.Removingthesystemfan4.Touchthestatic-protectivepackagethatc

Page 77 - Chapter6.Replacinghardware

•Toworkwithanotherpieceofhardware,gototheappropriatesection.•Tocompletethereplacement,goto“Completingthepartsreplacement”onpage164.Replacingtheheatsin

Page 78

5.Removethefourscrewsthatsecuretheheatsinktothesystemboard.Itisrecommendedthatyoucarefullyremovethefourscrewsusingthefollowingmethodtoavoidanypossible

Page 79 - Systemreliabilityguidelines

DocumentationDVDThedocumentationDVD,whichcomeswithyourserver,containsvariousdocumentsforyourserverinPortableDocumentFormat(PDF).Toviewthedocumentation

Page 80 - Removingtheservercover

9.Installthefourscrewstosecurethenewheatsinkonthesystemboard.Itisrecommendedthatyoucarefullyinstallthefourscrewsusingthefollowingmethodtoavoidanypossi

Page 81 - Chapter6.Replacinghardware67

DANGERDangerofexplosionifbatteryisincorrectlyreplaced.Whenreplacingthelithiumcoin-cellbattery,useonlythesameoranequivalenttypethatisrecommendedbythema

Page 82

7.Removetheoldcoin-cellbattery.Figure122.Removingthecoin-cellbattery8.Installanewcoin-cellbattery.Figure123.Installingthecoin-cellbattery9.Reinstallth

Page 83 - Reinstallingthecoolingshroud

CAUTION:Theheatsinksandmicroprocessorsmightbeveryhot.Turnofftheserverandwaitseveralminutestolettheservercoolbeforeremovingtheservercover.Beforeyoubegi

Page 84

15.Loosenthetwoscrewsthatsecurethesystemboard.Gentlylifteachedgeofthesystemboardslightlyupwardsothatthesystemboardisdisengagedfromthemountingstubsonth

Page 85 - Figure33.Removingthefrontdoor

19.Useacleaningpadtowipethethermalgreasefromtheheatsinksandthetopofthemicroprocessors.Disposeofthecleaningpadafterallofthethermalgreaseisremoved.20.Us

Page 86

b.Positionthemicroprocessorsocketcoverabovethemicroprocessorsocketsothatthesmalltriangle1onthesocketcoverfacesthesmalltriangle2onthemicroprocessorreta

Page 87 - Chapter6.Replacinghardware73

5.Removeallhot-swapredundantpowersupplies.See“Installingorreplacingahot-swapredundantpowersupply”onpage131.6.Recordthecomponentlocations,cableconnecti

Page 88

12.Ifyouareinstructedtoreturntheoldpowerinterfaceboard,followallpackaginginstructionsanduseanypackagingmaterialsthataresuppliedtoyouforshipping.Whatto

Page 89 - Chapter6.Replacinghardware75

4.Positiontheservercoveronthechassissothatthetabsontheservercoverarealignedwiththecorrespondinggapsinthechassis.Pivottheservercovertocloseit.Figure131

Page 90 - Memorymoduleinstallationrules

4ThinkServerTD350UserGuideandHardwareMaintenanceManual

Page 91 - Chapter6.Replacinghardware77

5.Lockthecoverlock2andcover-handlelock1.Figure132.Lockingthecoverlockandthecover-handlelock6.Reconnectexternalcablesandpowercordstotheserver.See“Rearv

Page 92

Chapter7.TroubleshootinganddiagnosticsThischapterprovidesinformationaboutbasictroubleshootinganddiagnosticmethodstohelpyousolveproblemsthatmightoccuri

Page 93 - Chapter6.Replacinghardware79

TheTSMimplementstheSELasspecifiedintheIPMI2.0specification.TheSELisaccessibleregardlessofthesystempowerstatethroughtheTSMin-bandandout-of-bandinterfaces

Page 94

SymptomActionTheopticaldriveisnotrecognized.1.Ensurethat:•Thesignalcableandconnectorarenotdamagedandtheconnectorpinsarenotbent.•Theopticaldriveissecur

Page 95 - Installingamemorymodule

SymptomActionAnewly-installedeasy-swapdriveisnotrecognized.1.Ensurethat:•Thesignalcableandconnectorarenotdamaged.•Theeasy-swap-drivemoduleissecurelyco

Page 96 - 1onthenewmemory

MemorymoduleproblemsFollowthesuggestedactionsforthecorrespondingsymptomintheorderinwhichtheyarelisteduntiltheproblemissolved.Ifnoneoftheseactionssolve

Page 97 - Removingamemorymodule

SymptomAction3.Replacethekeyboard.Themouseorpointingdevicedoesnotwork.1.Ensurethat:•Themouseorpointingdevicecableissecurelyconnectedtotheserver.IftheU

Page 98 - InstallingaPCIecard

Chapter8.Gettinginformation,help,andserviceThischaptercontainsinformationabouthelp,service,andtechnicalassistanceforproductsmanufacturedbyLenovoandwhe

Page 99 - Chapter6.Replacinghardware85

•Driversandsoftware•Diagnosticsolutions•Productandservicewarranty•Productandpartsdetails•Userguidesandmanuals•Knowledgebaseandfrequentlyaskedquestions

Page 100

Thewarrantydoesnotcoverthefollowing:•ReplacementoruseofpartsnotmanufacturedfororbyLenovoornon-warrantedLenovoparts•Identificationofsoftwareproblemsourc

Page 101 - RemovingaPCIecard

Chapter2.ServersetuproadmapThischapterprovidesageneralroadmaptoguideyouthroughsettingupyourserver.Theserversetupprocedurevariesdependingontheconfigurat

Page 102 - Figure50.RemovingthePCIecard

176ThinkServerTD350UserGuideandHardwareMaintenanceManual

Page 103 - InstallingtheSDmodule

AppendixA.NoticesLenovomaynotoffertheproducts,services,orfeaturesdiscussedinthisdocumentinallcountries.ConsultyourlocalLenovorepresentativeforinformat

Page 104 - RemovingtheSDmodule

TrademarksThefollowingtermsaretrademarksofLenovointheUnitedStates,othercountries,orboth:LenovoTheLenovologoTheThinkServerlogoThinkServerIntelandIntelX

Page 105 - Figure52.RemovingtheSDmodule

setforthinthisdocument,youmustimplementpracticesthatmaintainparticulateandgaslevelsthatareconsistentwiththeprotectionofhumanhealthandsafety.IfLenovode

Page 106

BatteryreturnprogramThisproductmaycontainalithiumorlithiumionbattery.Consultyourusermanualorservicemanualforspecificbatteryinformation.Thebatterymustbe

Page 107 - RemovingtheRAID110iupgradekey

RequirementsforBatteriesContainingPerchlorateThefollowingstatementappliestousersinthestateofCalifornia,U.S.A.CaliforniaPerchlorateInformation:Products

Page 108

DasProduktistnichtfürdenEinsatzanBildschirmarbeitsplätzenimSinne§2derBildschirmarbeitsverordnunggeeignet.ExportclassificationnoticeThisproductissubject

Page 109 - Chapter6.Replacinghardware95

Lenovo,Einsteinova21,85101Bratislava,SlovakiaWarning:ThisisaClassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhichcasetheuser

Page 110 - RemovingtheRAID510iupgradekey

EurasiancompliancemarkENERGYSTARmodelinformationENERGYSTAR®isajointprogramoftheU.S.EnvironmentalProtectionAgencyandtheU.S.DepartmentofEnergyaimedatsav

Page 111 - Installingtheflashmodule

Index2.5-inchdriveinstalling1342.5-inchhot-swap-drivebackplanelocations393.5-inchhot-swap-drivebackplanelocations38AaboutRAID58advancedSATAorSAShardwa

Page 112 - Removingtheflashmodule

Note:Beforeusingtheinformationandtheproductitsupports,besuretoreadandunderstandthefollowing:•TheReadMeFirstthatcomeswithyourproduct•“Safetyinformation

Page 113 - InstallingtheTSMPremium

6ThinkServerTD350UserGuideandHardwareMaintenanceManual

Page 114

guidelines63Hhardwarereplacing63heatsinkreplacing154help,getting173hot-swapinternalstoragedriveinstalling112replacing112hot-swappowersupplystatusLED23

Page 115 - RemovingtheTSMPremium

installing109replacing109optioncompletingthereplacement164Pparticulatecontamination178partsreplacement,completing164pass-throughlocations32pass-throug

Page 116

serverdocumentation2serverpackage7serversetuproadmap5service,getting173setting,changing,deletingpassword55SetupUtilityprogramEthernetconnector56exitin

Page 119 - Chapter6.Replacinghardware105

Chapter3.ProductoverviewThischaptercontainsthefollowingitems:•“Serverformfactor”onpage7•“Serverpackage”onpage7•“Features”onpage8•“Specifications”onpage

Page 120 - Figure62.RemovingtheTPM

Figure1.Serverpackage1Cablemanagementbar(availableonsomemodels)2Railkit(availableonsomemodels)3Keyboard4Server5Materialbox,includingpowercords,printed

Page 121 - Installingtheintrusionswitch

PowersupplyYourservercomeswithoneofthefollowingpowersupplyconfigurations:•Oneortwohot-swap550-wattpowersupplies(universalinputandcompliantwith80PLUSPla

Page 122 - Removingtheintrusionswitch

ExternaldrivesIfyourserverhasahostbusadapter(HBA)installed,anexternalstoragedevicecanbeconnectedtostoredata.Formoreinformation,refertothedocumentation

Page 123 - Chapter6.Replacinghardware109

•Securityfeatures–Servercoverlock(see“Servercoverlock”onpage24)–Administratorpasswordanduserpasswordtohelpprotectunauthorizedaccesstotheserver(see“Usi

Page 124

–Statuslight-emittingdiodes(LEDs)anddiagnosticLEDsForinformationabouttheLEDsforyourserver,refertotherelatedtopicsin“Locations”onpage16.–Softwareprogra

Page 125 - Chapter6.Replacinghardware111

180Vacfor750-wattredundantpowersuppliescompliantwith80PLUSTitanium•Maximum:264Vac•Inputfrequencyrange:47to63HzEnvironmentDependingonthehardwareconfigur

Page 126

Todownloadthesoftwareprograms,gototheLenovoSupportWebsiteathttp://www.lenovo.com/supportandfollowtheinstructionsontheWebpage.BIOSandTSMupdateutilities

Page 127 - Chapter6.Replacinghardware113

3.Selectthelanguageinwhichyouwanttoviewtheprogram.Then,followtheinstructionsonthescreentousetheprogram.BeforeinstallingaWindowsoraLinuxoperatingsystem

Page 128

ContentsSafetyinformation...iiiProductsthatarenotassessed...xSafetyinspectionguide...xGroundingrequirements...xiChapter

Page 129 - Chapter6.Replacinghardware115

LenovoThinkServerSystemManagerTheLenovoThinkServerSystemManager(TSM)isamanagementsolutionthatprovidescomprehensiveandsecuremanagementfeatures.Thesefea

Page 130

Thefollowingillustrationisanexampleofthemachinetype,model,andserialnumberlabelontheserver.Note:Dependingonthemodeltype,yourservermightlookdifferentfro

Page 131 - .Replacinghardware117

Frontviewofservermodelswithfifteen3.5-inch-drivebaysFrontviewofservermodelswithsixteen2.5-inch-drivebaysFigure3.Frontviewoftheserver1Optical-drivestatu

Page 132

6FrontpanelFordetailedinformationaboutthecontrol,connectors,andstatusLEDsonthefrontpanel,see“Frontpanel”onpage20.7Storage-drivebaysThestorage-drivebay

Page 133 - Chapter6.Replacinghardware119

FrontpanelThefollowingillustrationshowsthecontrol,connectors,andLEDsonthefrontpaneloftheserver.Note:Dependingonthemodel,yourservermightlookdifferentfr

Page 134

2SystemIDbuttonwithIDLEDWhenyoupressthesystemIDbutton,theIDLEDsonboththefrontandrearoftheserverarelit.Asaresult,youcanlocatetheserveramongotherservers

Page 135 - Figure78.Removingthetapedrive

Potentialsystemerror(systemhealthLED:amber)SolutionApowercordhasbeendisconnectedoraredundantpowersupplyhasbeenremoved.1.Ensurethatthepowersuppliesarei

Page 136 - 1totherearofthetapedrive

1Hot-swappowersuppliesYourservermodelmighthaveoneortwohot-swappowersupplies.Eachhot-swappowersupplyhasonepowercordconnectorontherear.Oneachpowersupply

Page 137 - Figure81.Openingthehandles

678EthernetRJ-45connectorsUsedtoattachanEthernetcableforaLAN.EachEthernetconnectorhastwostatusLEDstohelpyouidentifytheEthernetconnectivity,activity,an

Page 138 - Figure83.Donottouchthepins

Figure7.ServercoverlockServercomponentsToaccesstheinsideoftheserverandviewtheservercomponents,removetheservercover.See“Removingtheservercover”onpage66

Page 139 - Chapter6.Replacinghardware125

InstallingorremovingtheThinkServerSystemManagerPremium...99InstallingorremovingtheThinkServerTrustedPlatformModule...102Installingorr

Page 140 - Replacingthemicroprocessor

Thefollowingillustrationshowsthecomponentsofservermodelswithone3.5-inchhot-swap-drivebackplane.Figure8.Componentsofservermodelswithone3.5-inchhot-swap

Page 141 - Figure87.Openingthehandles

Thefollowingillustrationshowsthecomponentsofservermodelswithone2.5-inchhot-swap-drivebackplane.Figure9.Componentsofservermodelswithone2.5-inchhot-swap

Page 142

Thefollowingillustrationshowsthecomponentsofservermodelswithoneeasy-swap-drivemodule.Figure10.Componentsofservermodelswithoneeasy-swap-drivemodule1Eas

Page 143 - Figure90.Donottouchthepins

Notes:•BeforeservicingaLenovoproduct,ensurethatyoureadandunderstand“Safetyinformation”onpageiii.•UseonlypartsprovidedbyLenovo.DescriptionSelf-serviceC

Page 144

Hot-swap-driveLEDsThistopicappliesonlytoservermodelswithhot-swapinternalstoragedrives.Eachhot-swapstoragedrivehastwoLEDsonthefront.Figure11.Hot-swap-d

Page 145 - Chapter6.Replacinghardware131

Figure12.System-fanstatusLEDsSystem-fanstatusLEDColorDescriptionOffNoneThecorrespondingsystemfanisoperatingnormally.OnAmberThecorrespondingsystemfanis

Page 146

123Figure13.PowersupplystatusLEDsLEDStatusDescriptionActionOffThepowersupplyisdisconnectedfromtheacpowersource.Noactionisneeded.1InputstatusLEDOn,gree

Page 147 - Chapter6.Replacinghardware133

YourserversupportsthefollowingAnyRAIDadapter,RAIDcard,andpass-throughboard:AnyRAIDadapters(supportedtypevariesbyservermodel):•LenovoThinkServerRAID510

Page 148

LenovoThinkServerRAID720iAnyRAIDAdapterFigure15.LenovoThinkServerRAID720iAnyRAIDAdapter1ThinkServerRAIDSuperCapacitorModuleconnector(availableonsomemo

Page 149 - .Replacinghardware135

LenovoThinkServerRAID720ixAnyRAIDAdapterFigure16.LenovoThinkServerRAID720ixAnyRAIDAdapter1SATAconnectorUsedtoconnectthesignalcablefromtheinternaltaped

Page 150

SafetyinformationNote:Beforeusingtheproduct,besuretoreadandunderstandthemultilingualsafetyinstructionsonthedocumentationDVDthatcomeswiththeproduct.Ant

Page 151 - Chapter6.Replacinghardware137

LenovoThinkServer9286RAIDcardFigure17.LenovoThinkServer9286RAIDcard1ThinkServerRAIDSuperCapacitorModuleconnectorUsedtoconnecttheThinkServerRAIDSuperCa

Page 152 - Replacingthefront-panelboard

Hot-swap-drivebackplaneYourservercomeswithoneofthefollowingdrivebayandbackplaneconfigurations:•Five3.5-inch-drivebayswithonebackplane•Fifteen3.5-inch-d

Page 153 - .Replacinghardware139

3.5-inchhot-swap-drivebackplaneThefollowingillustrationsshowtheconnectorsona3.5-inchhot-swap-drivebackplane.Figure20.Frontviewofthe3.5-inchhot-swap-dr

Page 154

2.5-inchhot-swap-drivebackplaneThefollowingillustrationsshowtheconnectorsona2.5-inchhot-swap-drivebackplane.Figure22.Frontviewofthe2.5-inchhot-swap-dr

Page 155 - Chapter6.Replacinghardware141

2.ConnectthesingleconnectorontheotherendoftheYcabletotheAnyRAIDconnector1–2onthesystemboard.Tolocatetheconnectors,refertotherelatedtopicsin“Locations”

Page 156

SystemboardcomponentsThefollowingillustrationshowsthecomponentlocationsonthesystemboard.Figure24.Systemboardcomponents1Coin-cellbattery2System-boardsi

Page 157 - Chapter6.Replacinghardware143

1Coin-cellbatteryYourserverhasaspecialtypeofmemorythatmaintainsthedate,time,andconfigurationinformationforbuilt-infeatures.Thecoin-cellbatterykeepsthei

Page 158

16Optical-drive2signalconnectorUsedtoconnectthesignalcableofthesecondopticaldriveiftheserverhastwoopticaldrivesinstalled.17RAIDupgradekeyconnectorUsed

Page 159 - Chapter6.Replacinghardware145

SystemboardjumpersAjumperisashortlengthofconductorusedtosetuporadjustprintedcircuitboards,suchasthesystemboardofacomputer.Ajumperusuallyisencasedinano

Page 160

Thefollowingillustrationshowsthestatusofthejumpersonthesystemboardofyourserver.Figure26.SystemboardjumpersTable1.Systemboardjumpers1Clearpasswordjumpe

Page 161 - Chapter6.Replacinghardware147

PrzedskorzystaniemzproduktunależyzapoznaćsięzwielojęzycznymiinstrukcjamibezpieczeństwaznajdującymisięnapłycieDVDzdokumentacjądostarczonąwrazzproduktem

Page 162

4.Removethecoolingshroud.See“Removingthecoolingshroud”onpage69.5.Locatetheclearpasswordjumperonthesystemboard.Then,removeanypartsanddisconnectanycable

Page 163 - Chapter6.Replacinghardware149

3BIOSrecoveryjumperIfthepowertoyourserverisinterruptedwhiletheBIOSisbeingupdated,yourservermightnotrestartcorrectly.Ifthishappens,settheBIOSrecoveryju

Page 164

48ThinkServerTD350UserGuideandHardwareMaintenanceManual

Page 165 - Chapter6.Replacinghardware151

Chapter4.TurningonandturningofftheserverThischapterprovidesinformationaboutturningonandturningofftheserver.TurningontheserverTheservercanbeturnedonino

Page 166 - Replacingthesystemfan

•Theservermightbeturnedoffasanautomaticresponsetoacriticalsystemfailure.Notes:•Whenyouturnofftheserverandleaveitconnectedtoanacpowersource,theserveral

Page 167 - Chapter6.Replacinghardware153

Chapter5.ConfiguringtheserverThischapterprovidesthefollowinginformationtohelpyouconfiguretheserver:•“UsingtheSetupUtilityprogram”onpage51•“ConfiguringRAI

Page 168 - Replacingtheheatsink

TheSetupUtilityprogrammaininterfaceconsistsofthefollowingmenus:•“SystemInformationmenu”onpage52•“AdvancedSettingsmenu”onpage52•“SystemSecuritymenu”onp

Page 169 - Chapter6.Replacinghardware155

•MiscellaneousSettings:Viewandconfiguresomemiscellaneousitems,suchastheNumLockkeyonthekeyboardandthebootstatuscode.SystemSecuritymenuYoucansetpasswords

Page 170 - Replacingthecoin-cellbattery

TheSave&Exitmenucontainsthefollowingitems:•SaveChangesandReset:SavechangesandthencontinuewithfurtherconfigurationintheSetupUtilityprogram.•DiscardC

Page 171 - Chapter6.Replacinghardware157

•Haveatleasteightcharactersinlength•Containatleastonealphabeticcharacterandonenumericcharacter•Notbeyournameoryourusername•Notbeacommonwordoracommonna

Page 172

Statement1DANGERElectricalcurrentfrompower,telephone,andcommunicationcablesishazardous.Toavoidashockhazard:•Donotconnectordisconnectanycablesorperform

Page 173 - Chapter6.Replacinghardware159

3.PressF10tosavesettingsandexittheSetupUtilityprogram.Theserverwillfollowthestartupdevicesequenceyouhaveseteachtimeyouturnontheserver.ConfiguringtheTPM

Page 174

Systemprogramsarethebasiclayerofsoftwarebuiltintoyourserver.SystemprogramsincludethePOST,theUEFIBIOS,theSetupUtilityprogram,andtheTSMfirmware.ThePOSTis

Page 175 - Chapter6.Replacinghardware161

•UsingtheBIOSrecoveryjumper1.Removeallmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,disconnectallpowercordsfromelectricaloutletsandd

Page 176

ThefollowinglistdescribessomeofthemostcommonlyusedRAIDlevels:•RAID0:block-levelstripingwithoutparityormirroringSimplestripesetsarenormallyreferredtoas

Page 177 - Chapter6.Replacinghardware163

•RAID60:acombinationofRAID0andRAID6RAID60usesdistributedparity,withtwoindependentparityblocksperstripeineachRAIDset,anddiskstriping.ARAID60virtualdriv

Page 178 - Completingthepartsreplacement

documentalsoisavailableontheLenovoWebsiteat:http://www.lenovo.com/UserManualsUpdatingthefirmwareWhenyoureplaceadeviceintheserver,youmighthavetoeitherup

Page 179 - .Replacinghardware165

62ThinkServerTD350UserGuideandHardwareMaintenanceManual

Page 180 - Updatingtheserverconfiguration

Chapter6.ReplacinghardwareThischapterprovidesinstructionsonhowtoinstall,remove,orreplacehardwareforyourserver.Thischaptercontainsthefollowingitems:•“G

Page 181 - Viewingthesystemeventlog

•Ensurethatyouhaveanadequatenumberofproperlygroundedelectricaloutletsfortheserver,monitor,andotherdevices.•Backupallimportantdatabeforeyoumakechangest

Page 182 - Opticaldriveproblems

•Theuseofagroundingsystemisrecommended.Forexample,itisrecommendedtowearanelectrostaticdischarge(ESD)wriststrap,ifoneisavailable.EnsurethatyouworkinanE

Page 183 - Internalstoragedriveproblems

Statement3CAUTION:Whenlaserproducts(suchasCD-ROMs,DVDdrives,fiberopticdevices,ortransmitters)areinstalled,notethefollowing:•Donotremovethecovers.Removi

Page 184

RemovingtheservercoverAttention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”onpageiiiand“Guidelines”onpage63.

Page 185 - Memorymoduleproblems

4.Fullyopenthecoverhandleandslidetheservercovertotherearuntilitisdisengagedfromthechassis.Then,lifttheservercoveroffthechassisandsetitaside.Note:Itisr

Page 186

1.Oneachsideoftheserver,removethescrewsthatsecuretherackhandleandthenremovetherackhandlefromthechassis.Figure29.Removingtherackhandles2.Toreinstallthe

Page 187 - LenovoSupportWebsite

RemovingthecoolingshroudAttention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”onpageiiiand“Guidelines”onpage6

Page 188 - Callingforservice

Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanothercomputerforreference.Note:Dependingonthemodel,yourservermight

Page 189 - Purchasingadditionalservices

Toremoveandreinstallthefrontbezel,dothefollowing:1.Removeallmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,disconnectallpowercordsfro

Page 190

6.Pressthethreeplastictabsontherightsidefirst,andthenreleasethethreeplastictabsontheleftside.Then,pivotthefrontbezeloutwardtoremoveit.Figure34.Removing

Page 191 - AppendixA.Notices

7.Toreinstallthefrontbezel,alignthesixplastictabswiththecorrespondingnotchesinthechassis.Then,pressthefrontbezelinwarduntilitsnapsintoposition.Figure3

Page 192 - Particulatecontamination

•Alignthetwoplastictabsofthefrontdoorwiththecorrespondingholesinthechassis.Then,movethefrontdoorinwardandthenpullitslightlydownwarduntilitissecuredinp

Page 193 - RecyclinginformationforBrazil

4.Removethecoolingshroud.See“Removingthecoolingshroud”onpage69.5.ToremovethePCIecardholder,pressthereleasetab1andcarefullydisengagethePCIecardholderfr

Page 194 - Batteryreturnprogram

Statement6CAUTION:Ifyouinstallastrain-reliefbracketoptionovertheendofthepowercordthatisconnectedtothedevice,youmustconnecttheotherendofthepowercordtoa

Page 195 - EuropeanUnionRoHS

Installing,removing,orreplacinghardwareThistopicprovidesinstructionsonhowtoinstall,remove,orreplacehardwareforyourserver.Youcanexpandthecapabilitiesof

Page 196 - Electronicemissionnotices

ForalistofsupportedThinkServermemorymoduleoptions,goto:http://lenovoquickpick.com/usa/home/thinkserver/rack-and-tower-serverBeforeinstallingamemorymod

Page 197 - AppendixA.Notices183

Thefollowingtableexplainsthememorymoduleinstallationrulesforserversthathaveonlyonemicroprocessor(CPU1)installed.The“X”markindicatesthememoryslotsintow

Page 198 - ENERGYSTARmodelinformation

Table3.MemorymoduleinstallationrulesforserverswithtwomicroprocessorsCPU1DIMMCPU2DIMMA1A2B1B2C1C2D1D2A1A2B1B2C1C2D1D24DIMMsXXXX8DIMMsXXXXXXXX16DIMMsXXX

Page 199

Thefollowingtableexplainsthememorymoduleinstallationorderforserversthathavetwomicroprocessors(CPU1andCPU2)installed.Table7.Memorymoduleinstallationord

Page 200

Thefollowingtableexplainsthememorymoduleinstallationorderforserversthathaveonlyonemicroprocessor(CPU1)installed.Table10.Memorymoduleinstallationorderi

Page 201

7.Opentheretainingclipsoftheappropriatememoryslot.See“Memorymoduleinstallationrules”onpage76fortheinstallationsequenceinformation.Figure42.Openingther

Page 202

RemovingamemorymoduleAttention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”onpageiiiand“Guidelines”onpage63.B

Page 203

InstallingorremovingaPCIExpresscard:Ethernetcard,RAIDcard,orothersupportedtypesofPCIExpresscardsYourservercomeswithsevenPCIExpress(PCIe)cardslots.Depe

Page 204

7.PivotthelatchforthePCIecardslottotheopenposition.Figure45.PivotingthelatchforthePCIecardslottotheopenposition8.RemovethebracketforthePCIecardslot.St