Lenovo 6528 User Manual Page 182

  • Download
  • Add to my manuals
  • Print
  • Page
    / 216
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 181
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the Parts Listing section in the Hardware Maintenance Manual to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Memory DIMM Configuration Error
for All DIMMs on Memory Subsystem
All DIMMs.
Error A DIMM configuration error
has occurred.
Make sure that DIMMs are
installed in the correct sequence
and have the same size, type,
speed, and technology.
Memory uncorrectable error detected
for DIMM One of the DIMMs on
Memory Subsystem One of the
DIMMs.
Error A memory uncorrectable
error has occurred.
1. If the server failed the POST
memory test, reseat the
DIMMs.
2. Replace any DIMM that is
indicated by a lit error LED.
Note: You do not have to
replace DIMMs by pairs.
3. Run the Setup utility to enable
all the DIMMs.
4. Run the DSA memory test.
Memory Logging Limit Reached for
DIMM One of the DIMMs on Memory
Subsystem One of the DIMMs.
Error The memory logging limit
has been reached.
1. Update the server firmware to
the latest level.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
2. Reseat the DIMMs and run
the DSA memory test.
3. Replace any DIMM that is
indicated by a lit error LED.
Memory DIMM Configuration Error
for One of the DIMMs on Memory
Subsystem One of the DIMMs.
Error A DIMM configuration error
has occurred.
Make sure that DIMMs are
installed in the correct sequence
and have the same size, type,
speed, and technology.
Memory uncorrectable error detected
for DIMM n Status on Memory
Subsystem DIMM n Status.
(n = DIMM number)
Error A memory uncorrectable
error has occurred.
1. If the server failed the POST
memory test, reseat the
DIMMs.
2. Replace any DIMM that is
indicated by a lit error LED.
Note: You do not have to
replace DIMMs by pairs.
3. Run the Setup utility to enable
all the DIMMs.
4. Run the DSA memory test.
5. (Trained service technician
only) Replace the system
board.
166 ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Installation and User Guide
Page view 181
1 ... 181 182 183 ... 216

Comments to this Manuals

No comments