IBM System x3500 M4 24
Physical and electrical specifications
Dimensions and weight (approximate):
Tower:
Width: 218 mm (8.6 in)
Depth: 750 mm (29.5 in)
Height: 440 mm (17.3 in)
Weight:
Minimum configuration: 25.0 kg (55.1 lb)
Maximum configuration: 39.8 kg (87.7 lb)
Rack (using the Tower-to-Rack Conversion Kit, 81Y7006):
Width: 424 mm (16.7 in)
Depth: 702 mm (27.6 in)
Height: 218 mm (8.5 in)
Weight:
24.5 kg (53.9 lb) (minimum configuration)
39.3 kg (86.6 lb) (maximum configuration)
Supported environment:
Air temperature
Server on: 10 - 35 °C (50 to 95 °F); altitude: 0 - 915 m (3,000 ft)
Server on: 10 - 32 °C (50 - 90 °F); altitude: 915 m (3,000 ft) - 2,134 m (7,000 ft)
Server on: 10 - 28 °C (50 - 83 °F); altitude: 2,134 m (7,000 ft) - 3,050 m (10,000 ft)
Server off (with standby power): 5 - 45 °C (41.0 - 113 °F)
Shipping: -40 - 60 °C (-40 - 140 °F)
Humidity
Server on: 20 - 80% , Max. Dew Point 21 °C, Max. rate of change 5 °C/hr
Server off: 8 - 80%, Max. Dew Point 27 °C
Electrical
Models with 900 W power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 11 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 5.5 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.6 kVA
Maximum configuration: 1.1 kVA
Models with 750 W power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 8.9 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 4.5 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.6 kVA
Maximum configuration: 0.9 kVA
BTU output
Minimum configuration: 2013 Btu/hr (590 watts)
Maximum configuration: 3610 Btu/hr (1056 watts)