Lenovo Flex System x240 M5 User's Guide Page 33

  • Download
  • Add to my manuals
  • Print
  • Page
    / 39
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 32
Lenovo Flex System x240 M5 Product Guide 33
Physical specifications
The server features the following dimensions and weight (approximate):
Height: 51 mm (2.0 in)
Depth: 493 mm (19.4 in)
Width: 215 mm (8.5 in)
Maximum weight: 7.1 kg (15.6 lb)
The server features the following shipping dimensions and weight (approximate):
Height: 197 mm (7.8 in)
Depth: 603 mm (23.7 in)
Width: 430 mm (16.9 in)
Weight: 8 kg (17.6 lb)
Supported environment
The Flex System x240 M5 compute node complies with ASHRAE Class A3 specifications.
The following Power on operating environment is supported:
Temperature: 5 - 40 °C (41 - 104 °F)
Humidity, non-condensing: -12 °C dew point (10.4 °F) and 8 - 85% relative humidity
Maximum dew point: 24 °C (75 °F)
Maximum altitude: 3048 m (10,000 ft)
Maximum rate of temperature change: 5 °C/hr (41 °F/hr)
The following Power off operating environment is supported:
Temperature: 5 - 45 °C (41 - 113 °F)
Relative humidity: 8 - 85%
Maximum dew point: 27 °C (80.6 °F)
The following Storage (non-operating) operating environment is supported:
Temperature: 1 - 60 °C (33.8 - 140 °F)
Altitude: 3050 m (10,006 ft)
Relative humidity: 5 - 80%
Maximum dew point: 29 °C (84.2°F)
The following Shipment (non-operating) environment is supported:
Temperature: -40 - 60 °C (-40 - 140 °F)
Altitude: 10,700 m (35,105 ft)
Relative humidity: 5 - 100%
Maximum dew point: 29 °C (84.2 °F)
Page view 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 39

Comments to this Manuals

No comments