ThinkServer RS110 Ty pes 6435, 6436, 6437 and 6438User Gui de
Statement 2: CAUTION: When replacing the lithium battery, use only the battery recommended by the manufacturer. If your system has
Statement 3: CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note t
Statement 4: ≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) ≥ 55 kg (121.2 lb) CAUTION: Use safe practices when lifting. Statemen
Statement 8: CAUTION: Never remove the cover on a power supply or any part that has the following label attached. Hazardous vol
xii ThinkServer RS110 Types 6435, 6436, 6437 and 6438: User Guide
Chapter 1. The ThinkServer RS110 Types 6435, 6436, 6437 and 6438 The Lenovo® ThinkServer™ RS110 Types 6435, 6436, 6437 and 6438 serve
additional information that is not included in the server documentation. These updates are available from the Lenovo Support Web sit
Features and specifications The following information is a summary of the features and specifications of the server. Depending on the
Table 1. Features and specifications Microprocessor:One Intel® LGA 775 single core, dual core, or quad core, depending on the server m
What your server offers The server uses the following features and technologies: v Baseboard management controller The baseboard mana
The server supports up to two 25.4 mm (1-inch) slim-high, 3.5-inch hard disk drives (Serial Advanced Technology Attachment (SATA) or
EasyStartup The ThinkServer EasyStartup program simplifies the process of installing the operating system and device drivers on your s
Note: If this LED is off, it does not mean that there is no electrical power in the server. The LED might be burned out. To r
Serial connector: Connect a 9-pin serial device to this connector. Video connector: Connect a monitor to this connector. Ethernet con
Statement 5: CAUTION: The power control button on the device and the power switch on the power supply do not turn off the elect
Chapter 2. Installing optional devices This chapter provides detailed instructions for installing optional hardware devices in the serv
1 Riser card assembly 12 Bezel 2 SAS/SATA controller (some models) 13 3.5-inch hot-swap hard disk drive (some models) 3 Sys
2.5-inch models Chapter 2. Installing optional devices 13
1 Riser card assembly 11 CD/DVD drive 2 SAS/SATA controller (some models) 12 3.5-inch hot-swap hard disk drive (some models)
Important: Use only a supported SAS/SATA controller in the SAS/SATA controller card connector. For a list of supported optional devi
ThinkServer RS110 Ty pes 6435, 6436, 6437 and 6438User Gui de
System-board external connectors The following illustration shows the external connectors on the system board. 1 Serial connector
System-board LEDs The following illustration shows the light-emitting diodes (LEDs) on the system board. 1 PCI Express slot 2 er
System-board optional-device connectors The following illustration shows the connectors for user-installable optional devices. 1 Oth
The following illustration shows the location of the PCI-X slot on the optional PCI-X riser-card assembly. 1 Power cable 2 PCI
v Do not attempt to lift an object that you think is too heavy for you. If you have to lift a heavy object, observe the fol
Working inside the server with the power on Attention: Static electricity that is released to internal server components when the s
2. Turn off the server and all attached devices (see “Turning off the server” on page 9). 3. Disconnect all external cables an
connectors” on page 18 for the location of the connector). To install the Remote Supervisor Adapter II SlimLine, see the documentat
3. Remove the cover (see “Removing the cover” on page 21). 1 Power cable 2 PCI X-slot 4. If the riser-card assembly i
8. Place the adapter, component side up, on a flat, static-protective surface and set any jumpers or switches as described by th
Note: Before using this information and the product it supports, read the general information in “Notices,” on page 47 and the War
12. If the riser-card assembly is an optional PCI-X riser-card assembly in the server, reconnect the riser-card power cable to th
Note: If you have only one hard disk drive, install it in the left drive bay. 1 SATA hard disk drive back plate 3 Hard
Installing a hot-swap hard disk drive The 3.5-inch drive hot-swap server models support either two SAS 3.5-inch hard disk drives or
d. Push the tray handle to the closed (locked) position. e. Check the hard disk drive status LED to make sure that the hard
4. Remove the retention clip 1 from the drive and save it for future use.To install a CD or DVD drive, complete the followi
a. Separate the P4 connector on the cable that connects the power supply to the CD/DVD interposer card. b. Connect the short 4
6. Install a PCI-X or PCI adapter 1, if you have one available: a. Remove the expansion-slot cover from the PCI-X slot on
8. Connect the riser-card power cable 1 to the PCI-X riser-card assembly 2.If you have to remove the PCI-X riser-card assemb
v When you restart the server after you add or remove a DIMM, a message is displayed indicating that the memory configuration h
Completing the installation To complete the installation, complete the following steps: 1. Reinstall the cover. See “Installing the
Contents Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . .v Chapter 1. The ThinkServer RS110 Types 643
Rear 1 Power-cord connector 5 Ethernet 1 connector 2 Systems-management connector 6 Ethernet 2 connector 3 USB 3 connector
Chapter 3. Configuring the server The following configuration programs come with the server: v Configuration/Setup Utility program The
Using the Configuration/Setup Utility program Use the Configuration/Setup Utility program to perform the following tasks: v View conf
v Devices and I/O Ports Select this choice to view or change assignments for devices and input/output (I/O) ports, to configure r
example, you can define a startup sequence that checks for a CD or DVD in the CD or DVD drive, then checks the hard disk drive
together with the BMC Serial Port Access Mode setting, affects serial-related behavior and remote-management capabilities on this serv
Select this choice to view the system-error messages from the Remote Supervisor Adapter II SlimLine. To clear the RSA II event/error
If you forget the power-on password, you can regain access to the server in any of the following ways: v If an administrator pa
Note: All configuration settings will be cleared by this action; you might have to configure the settings again. 1. Review the sa
Boot Support Specify the type of boot support that will be in effect (disabled, BIOS only, OS only, or both BIOS and OS) RAID Pro
Waste electrical and electronic equipment (WEEE) notices . . . . . . . . .49 Recycling statements for Japan . . . . . . . .
Using the baseboard management controller firmware update utility program Use the baseboard management controller firmware update utilit
Appendix. Notices Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your
estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific
Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives and population of all hard disk
dispositions de retour et de recyclage applicables aux systèmes utilisés à travers l’Union européenne. Conformément à la directive, l
Battery return program This product may contain a lithium or lithium ion battery. Consult your user manual or service manual for sp
batteries pour indiquer que la batterie ne doit pas être mise au rebut mais plutôt récupérée en fin de cycle de vie selon cette
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not
empfohlene Kabel angeschlossen werden. Lenovo übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt
Taiwanese Class A warning statement Lenovo product service information for Taiwan Chinese Class A warning statement Korean Clas
Safety Before installing this product, read the Safety Information. Antes de instalar este produto, leia as Informações de Seguranç
56 ThinkServer RS110 Types 6435, 6436, 6437 and 6438: User Guide
Index Aadapterinstalling 22 PCI Express bus 22 administrator password 39, 43 attention notices 2 Bbaseboard management controller utility
integrated (continued)functions 4 internal connectors 14 Jjumper, clear CMOS (password override) 43 jumpers 15 LLEDEthernet activity 8 Eth
Ttemperature 4 trademarks 48 turning off the server 9 turning on the server 9 TÜV gloss statement 52 Uunknown password, bypassing 43 u
60 ThinkServer RS110 Types 6435, 6436, 6437 and 6438: User Guide
Part Number: 46U0854 Printed in USA (1P) P/N: 46U0854
Antes de instalar este producto, lea la información de seguridad. Läs säkerhetsinformationen innan du installerar den här produkten.
Statement 1: DANGERElectrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do