Note:ThenumberonthelabelforeachofthefourSATAsignalcablesindicatesthesequencetofollow
whenyouareconnectingthecablestothecorrespondingSATAconnectors(0-3)onthesystemboard.
SATAsignalcablelabelSystemboardSATAconnector
P0
SATAconnector0
P1
SATAconnector1
P2
SATAconnector2
P3
SATAconnector3
ForinformationaboutconfiguringRAIDusingtheconfigurationutilityfortheThinkServerRAID100,see
“ConfiguringthesystemBIOStoenableonboardSATARAIDfunctionality”onpage59
.
Refertothefollowingtopicsforinformationabouttheconnectorlocations:
•“Hot-swaphard-disk-drivebackplane”onpage32
•“Systemboardcomponents”onpage39
Connectingthemini-SASsignalcablesfromtheRAIDcardtothebackplanesfor
servermodelswithhot-swapharddiskdrives
IfyourserverhasasupportedRAIDcardinstalled,youcanconnectthemini-SASsignalcablesfromthe
RAIDcardtothebackplanestosupportuptoeightharddiskdrives.Inthiscase,youcanconfigureRAIDfor
theharddiskdrivesusingtheadvancedhardwareRAIDfunctions.
Note:TheoptionpackagefortheRAIDcardisdesignedfordifferenttypesofserversandmightcontain
additionalcablesthatarenotrequiredforinstallation.