Table 13. EasyLED panel LEDs (continued)
LED Description Action
CPU A microprocessor has
failed.
1. Make sure that the failing microprocessor,
which is indicated by a lit LED on the
system board, is install correctly.
2. (Trained service technician only) Replace
the microprocessor.
DASD A hard disk drive error has
occurred.
1. Check the LEDs on the hard disk drives and
replace the hard disk drive with the lit LED.
2. Replace the hard disk drive backplane.
RAID A RAID controller error
has occurred.
1. Make sure that a RAID controller is installed
correctly.
2. Check the system-error log for information
about the error.
BRD An error has occurred on
the system board.
1. Check the LEDs on the system board to
identify the component that caused the error.
2. Check the system-error log for information
about the error.
Diagnostic programs and messages
The diagnostic programs are the primary method of testing the major components
of the server. As you run the diagnostic programs, text messages are displayed on
the screen and are saved in the test log. A diagnostic text message indicates that a
problem has been detected and provides the action you should take as a result of
the text message. Please see the Hardware Maintenance Manual for additional
information on diagnostic programs and messages.
Power-supply diagnostics
The following minimum configuration is required for the dc LED on the power supply
to be lit:
v Power supply
v Power cord
The following minimum configuration is required for the server to start:
v One microprocessor in microprocessor socket 1
v One 1 GB DIMM on the system board
v One power supply
v Power cord
v Six cooling fans
Chapter 7. Solving problems 163