Ifyouhavejustaddednewsoftwareoranewoptionaldeviceandtheserverisnotworking,dothefollowing
beforeusingthetroubleshootingtables:
1.Checkthesystem-errorLEDontheoperatorinformationpaneltoseeifitislit.
2.Removethesoftwareordevicethatyoujustadded.
3.Runthediagnosticteststodeterminewhethertheserverisrunningcorrectly.
4.Reinstallthenewsoftwareornewdevice.
Harddiskdrivebooterror
Aharddiskdrivebooterrorcanhavethefollowingcauses.
SymptomFRU/Action
Thestartupdriveisnotinthebootsequencein
conguration.
Checkthecongurationandensurethestartupdriveis
inthebootsequence.
Nooperatingsystemisinstalledonthebootdrive.Installanoperatingsystemonthebootdrive.
Thebootsectoronthestartupdriveiscorrupted.
Thedrivemustbeformatted.Dothefollowing:
1.Attempttobackupthedataonthefailingharddisk
drive.
2.Usingtheoperatingsystemprograms,formatthe
harddiskdrive.
Thedriveisdefective.
Replacetheharddiskdrive.
Powersupplyproblems
Ifyoususpectapowersupplyproblem,usethefollowingprocedures.
Check/VerifyFRU/Action
Checkthefollowingforproperinstallation.
•Powercord
•On/Offswitchconnector
•On/Offswitchpowersupplyconnector
•Systemboardpowersupplyconnectors
•Microprocessorconnection
Reseatconnectors.
Checkthepowercordforcontinuity.
Powercord
Checkthepower-onswitchforcontinuity.
Power-onswitch
Beepsymptoms
Beepsymptomsaretonesoraseriesoftonesseparatedbypauses(intervalswithoutsound)duringthePOST.
Thefollowingtabledescribesbeepsymptomsandprovidessuggestedactionstocorrectdetectedproblems.
86ThinkServerTS130HardwareMaintenanceManual