Note:ThefollowingstepsarebasedonthescenariothatSecureCRTisstarted.Ifyouareusinga
differentserial-connectorconfigurationprogram,theprocedureissimilar.
3.Onthemenubar,clickFile➙QuickConnect.TheQuickConnectwindowisdisplayed.
4.ConfiguretheDB9serialconnectorasthefollowing:
Protocol:Serial
Port:COMx(xreferstotheserialnumberoftheDB9serialconnector)
Baudrate:115200
Databits:8
Parity:none
Stopbits:1
5.CleartheRTS/CTScheckbox,andthenclickConnect.Thestoragearrayisconnectedtothecomputer.
6.Enterlenovointhemainwindow.TheSerialDebugMenuisdisplayed.
7.Enterthenumberthatrepresentsthemenuyouwanttoopen.Then,followtheinstructionsonthescreen.
Note:Toopenthehelpinformationsystemoftheprogram,enterh.
Basictroubleshooting
Usethebasictroubleshootinginformationtofindsolutionstoproblemsthathavedefinitesymptoms.
Symptom:
Theservercannotdetecttheconnectedstoragearray.
Actions:
1.EnsurethattherearI/Omodulesaresecuredtothechassisandconnectedtotheconnectorsonthe
rearofthebackplane.
2.EnsurethattheSASsignalcablesaresecurelyconnectedtothecorrectconnectorsontherearI/O
modules.
3.EnsurethattheSASsignalcablesaresecurelyconnectedtothecorrectconnectorsontheRAID
cardorHostBusAdapterinstalledintheserver.
4.Checkthepower-statusLEDonthefrontpanel.IftheLEDisnotlitingreen,dooneorallofthefollowing:
•Disconnectandreconnectthepowercords.
•Removeandreinstallthepowersupplies.
5.Connectthestoragearraytotheserveragainandcheckiftheservercandetectthestoragearray.
6.CheckthestatusLEDsontherearI/OmodulestoensurethattherearI/Omodulesareworkingnormally.
Symptom:
ThecolorofsomeLEDsonthefrontpanelindicatespotentialsystemerrors.
Actions:
1.Ensurethattheambienttemperatureiswithintherequiredrangeofthestoragearray.
2.Ifthepower-statusLEDisnotlitingreen,checkthat:
•Thepowercordisworkingcorrectly.
•Thepowersupplyisworkingnormally.Replacethepowersupplyifnecessary.
60ThinkServerStorageSA120UserGuideandHardwareMaintenanceManual