Lenovo ThinkServer RD550 User Manual Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 184
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
2SystemhealthLED
ThesystemhealthLEDhelpsyoutodetermineifthereareanysystemerrors.
Off:Theserverisoffortheserverisonandworkingcorrectly.
Amber:Theserverhaspotentialsystemerrors.Checktheinformationinthefollowingtableforpotential
systemerrorsandcorrespondingsolutions.
Blinking:Systeminitializationisongoing.
Potentialsystemerror(systemhealthLED:amber)Solution
Thetemperatureoftheserverreachedthenon-critical
temperaturethreshold.
ChecktheBMCforerrorsandcheckthesystemfans.
Thevoltageoftheserverreachedthenon-criticalvoltage
threshold.
Replacethesystemboard.
Note:ThisactionmustbeperformedonlybyLenovo
servicepersonnel.SeeChapter8“Gettinginformation,
help,andservice”onpage153
.
Afanisrunningatlowspeed.
Checkthesystemfans.
Ahot-swapfanhasbeenremoved.1.Ensurethatthesystemfansareconnectedsecurely
tothesystemboard.
2.Reinstalltheremovedfanorinstallanewfanto
replacetheremovedfan.
Thepowersupplyhasacriticalerror.
ChecktheBMCfordetailedinformation.
Apowercordhasbeendisconnectedoraredundant
powersupplyhasbeenremoved.
1.Ensurethatthepowersuppliesareinstalledsecurely.
2.Ensurethatthepowercordsareconnectedsecurely
tothepowersupplies.
3.Installanewpowersupplytoreplacetheremoved
one.
Thesystemisoverheated.
ChecktheBMCforerrorsandthencheckthesystem
fans.
3PowerbuttonwithpowerstatusLED
Youcanpressthepowerswitchtoturnontheserverwhenyoufinishsettinguptheserver.Youalsocan
holdthepowerswitchforseveralsecondstoturnofftheserverifyoucannotturnitofffromtheoperating
system.SeeChapter4“Turningonandturningofftheserveronpage47.ThepowerstatusLEDhelpsyou
todeterminethecurrentpowerstatus.
StatusColor
Description
OnGreen
Theserverison.
Off
None
Theserverisoff.
20ThinkServerRD550UserGuideandHardwareMaintenanceManual
Page view 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 183 184

Comments to this Manuals

No comments