The following notes describe the types of drives that the server supports and other
information that you must consider when installing a drive:
v Make sure that you have all the cables and other equipment that is specified in
the documentation that comes with the drive.
v Select the bay in which you want to install the drive.
v Check the instructions that come with the drive to see whether you have to set
any switches or jumpers on the drive. If you are installing a SAS or SATA device,
be sure to set the SAS or SATA ID for that device.
v Optional internal or external USB diskette drives, tape drives, DVD-ROM, and
multiburner drives are examples of removable-media drives. You can install
removable-media drives in bays 1, 2, and 3 only.
v The SATA removable-media drives that you install in bay 1 connects to the SATA
4 connector on the system board and the drive in bay 2 connects to the SATA 5
connector on the system board.
v To install a 3.5-inch drive in a 5.25-inch bay, you must use the 5.25-inch
conversion kit.
v The electromagnetic interference (EMI) integrity and cooling of the server are
protected by having all bays and PCI and PCI Express slots covered or
occupied. When you install a drive, PCI, or PCI Express adapter, save the EMC
shield and filler panel from the bay or PCI or PCI Express adapter slot cover in
the event that you later remove the device.
v See http://www.lenovo.com/thinkserver and click the Options tab for a list of
supported options.
Removing a DVD drive
To remove a DVD drive, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 29.
2. Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
3. Unlock and remove the side cover (see “Removing the side cover” on page 32).
4. Remove the lower bezel, and then remove the upper bezel (see “Removing the
two-piece bezel” on page 34).
5. Disconnect the power and signal cables from the drive that is to be removed.
6. Press and hold the blue release button on the side of the bay to release the
drive; then, pull the drive out of the front of the server.
44 ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Installation and User Guide