2. Turn off the server and peripheral devices and disconnect the power cords.
3. Remove the cover (see “Removing and installing the cover” on page 119).
4. Remove the riser-card assembly (see “Removing the riser-card assembly” on page 157).
5. Unlock the retention latch on the USB connector by squeezing the two retention clips toward each
other (see “System-board internal connectors” on page 107.
6. Grasp the flash device and pull to remove it from the connector.
7. Press down on the retention latch to return it to the locked position.
8. If you are instructed to return the flash device, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Installing a USB embedded hypervisor flash device
To install a hypervisor flash device, complete the following steps:
1. Read the safety information in “Important Safety Information” on page 1 and “Guidelines for trained
service technicians” on page 115.
2. Turn off the server and peripheral devices and disconnect the power cords.
3. Remove the cover (see “Removing and installing the cover” on page 119).
4. Remove the riser-card assembly (see “Removing the riser-card assembly” on page 157) (see
“System-board internal connectors” on page 107.
5. Unlock the retention latch on the USB connector by squeezing the two retention clips toward each
other (see “System-board internal connectors” on page 107.
6. Align the flash device with the USB connector on the system board and push it into the USB
connector until it is firmly seated.
7. Press down on the retention latch to lock the flash device into the USB connector.
8. Install the riser-card assembly (see “Installing the riser-card assembly” on page 158).
9. Go to “Completing the FRU replacement” on page 173.
Replacing the operator information panel assembly
To replace the operator information panel assembly, use the following procedures:
Removing the operator information panel assembly
To remove the operator information panel assembly, complete the following steps.
1. Read the safety information in “Important Safety Information” on page 1 and “Guidelines for trained
service technicians” on page 115.
2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables.
3. Remove the server from the rack and remove the cover (see “Removing and installing the cover” on
page 119).
4. Disconnect both cables from the operator information panel assembly.
5. Remove the screws that secure the operator information panel assembly to the DVD bay housing.
134 ThinkServer ThinkServer RS210, Types 6531, 6532, 6533, and 6534: Hardware Maintenance Manual